Customer Service
Site Map
Home
Search Site
Products and ServicesIndustry NewsYour IndustryInternational MarketsContact UsInside Coen

< Back
Custom Designed Duct Burner
PowerPlus Duct Burner
Standard Gas- Fired Duct Burner
Standard Oil- Fired Duct Burner

 

Duct Burner General Information
Aftermarket
 
Click on image below to download a PDF of the brochure.
Duct Burners for Cogeneration
Aftermarket
Click here to order a hard copy of the brochure.

Duct Burner Aftermarket

Duct Burner Aftermarket
  • Reliability
  • Fast Turnaround
  • One-Source Responsibility
  • Added Capacity
  • Lower Emissions
  • Peak Power
Innovative Solutions For Your Duct Burner Retrofit

Innovation comes from Coen's commitment to research, development and testing that is unparalleled in the combustion industry today.

Solutions using the latest burner technology:

  • Overall System Evaluation
  • Low Emission Replacement Elements
  • Available CFD Modeling

Experience comes from focusing on customer needs, developing new products, and doing it well, year after year.

Superior performance in a changing world:

  • Experienced Nationwide Network of Factory-Trained Technicians
  • Supplying Duct Burners for Over 30 Years
  • Largest Installation Base

Absolute confidence comes from our capability to stand behind our products and offer value to our customers.

Reliable performance when you need it:

  • Time-Tested Products
  • Fast Turnaround
  • Rugged, Durable Design

Generating Station Retrofits to Coen Duct Burner

A generating station in California produced an unusually high turbine exhaust gas (TEG) velocity of approximately 13,000 ft/min in the burner area. This led to unreliable light-offs, nonstop maintenance by plant personnel and a continuous pilot to maintain flame stability. The plant needed a new duct burner to withstand this high velocity TEG steam, provide a 10:1 turndown ratio and supply good flame stability to meet increased demand for reliable power.

Solution

Coen's vertical element duct burner provided a unique retrofit solution. Engineered specifically to fit into the existing space, the accessible four gas inlets were split into eight vertical burner elements (See Figure 1). The new design also included a horizontal ribbon pilot upstream of the vertical elements that provided reliable burner light-off.

Coen's unique design easily fit into the small duct section while using the existing inlet piping. In addition, the vertical elements provided a superior balanced temperature profile going into the split vertical boiler.

Results

The Coen Duct Burner Retrofit exceeded all the performance guarantees for capacity, temperature profile, flame stability and turndown. The generating station now operates reliably and with confidence throughout the year.